Product Details
For central heating systems, HVAC hydronic pipelines and multi-branch water circulation projects suffering from unbalanced flow and pressure deviation, pressure differential valve is the key hydraulic control component to stabilize pipeline pressure difference. Designed for automatic pressure balance of closed circulating water systems, this valve maintains a constant pressure difference between water supply and return pipes, effectively solving uneven heating and flow disorder problems in complex pipe networks.
Drawing of pressure differential valve

Drawing of main valve

Component 01
| No. | Description | Material | Standard |
| 1 | Cap | Plastic | ABS |
| 2 | Adjusting Screw | Stainless Steel | AISI 304 |
| 3 | Jam Nut | Stainless Steel | AISI 304 |
| 4 | Spring table | Stainless Steel | AISI 304 |
| 5 | Bonnet | Stainless Steel | AISI 304 |
| 6 | Spring | Spring Steel | SiCrV |
| 7 | Nut | Stainless Steel | A2 |
| 8 | Spring table | Spring Steel | Mn-steel+Ni Plated |
| 9 | Fixing Holder | Stainless Steel | AISI 304 |
| 10 | Screw | Stainless Steel | A2 |
| 11 | Diaphragm | NylonReinforced Rubber | EPDM+Nylon |
| 12 | Gasket | Stainless Steel | AISI 304 |
| 13 | O-Ring | Rubber | NBR |
| 14 | Internal Body | Stainless Steel | AISI 304 |
| 15 | O-Ring | Rubber | NBR |
| 16 | O-Ring | Rubber | NBR |
| 17 | Stem | Stainless Steel | AISI 304 |
| 18 | Disc | Stainless Steel+Rubber | AISI 304+EPDM |
| 19 | Body | Stainless Steel | AISI 304 |
| 20 | O-Ring | Rubber | NBR |
Component 02
| No. | Description | Material | Standard |
| 1 | Body | Ductile Iron | GJS 500-7 |
| 2 | Seat | Stainless Steel | AISI 304/316 |
| 3 | O-ring | Rubber | NBR |
| 4 | O-ring | Rubber | NBR |
| 5 | Bolt | Stainless Steel | A2/A4 |
| 6 | Washer | Stainless Steel | A2/A4 |
| 7 | Bonnet | Ductile Iron | GJS 500-7 |
| 8 | Bush | Brass | C61900 |
| 9 | Spring | Stainless Steel | AISI 304/316 |
| 10 | Caulking Nut | Stainless Steel | A4 |
| 11 | Diaphragm | Nylon Reinforced Rubber | EPDM +Nylon Fabric |
| 12 | Fixing holder | Ductile Iron | GJS 500-7 |
| 13 | Disc Holder | Ductile Iron | GJS 500-7 |
| 14 | Seal | Rubber | EPDM |
| 15 | Seat Retainer | Stainless Steel | AISI 304/316 |
| 16 | Stem | Stainless Steel | AISI 304/316 |
| 17 | Plug | Stainless Steel | AISI 304/316 |
| 18 | Screw | Stainless Steel | A2/A4 |
| 19 | Plug | Stainless Steel | A2/A4 |
| 20 | Washer | Stainless Steel | A2/A4 |
dimension
| DN | L | H | ØD | ØK | N-Ød | ØB | ||||||||
| PN10 | PN16 | PN25 | PN10 | PN16 | PN25 | PN10 | PN16 | PN25 | PN10 | PN16 | PN25 | |||
| 50 | 230 | 177 | 165 | 165 | 165 | 125 | 125 | 125 | 4-Ø19 | 4-Ø19 | 4-Ø19 | Ø99 | Ø99 | Ø99 |
| 65 | 290 | 202 | 185 | 185 | 185 | 145 | 145 | 145 | 4-Ø19 | 4-Ø19 | 8-Ø19 | Ø118 | Ø118 | Ø118 |
| 80 | 310 | 219 | 200 | 200 | 200 | 160 | 160 | 160 | 8-Ø19 | 8-Ø19 | 8-Ø19 | Ø132 | Ø132 | Ø132 |
| 100 | 350 | 243 | 220 | 220 | 235 | 180 | 180 | 190 | 8-Ø19 | 8-Ø19 | 8-Ø23 | Ø156 | Ø156 | Ø156 |
| 125 | 400 | 243 | 250 | 250 | 270 | 210 | 210 | 220 | 8-Ø19 | 8-Ø19 | 8-Ø28 | Ø156 | Ø156 | Ø156 |
| 150 | 480 | 333 | 285 | 285 | 300 | 240 | 240 | 250 | 8-Ø23 | 8-Ø23 | 8-Ø28 | Ø211 | Ø211 | Ø211 |
| 200 | 600 | 428 | 340 | 340 | 360 | 295 | 295 | 310 | 8-Ø23 | 12-Ø23 | 12-Ø28 | Ø266 | Ø266 | Ø274 |
| 250 | 730 | 478 | 405 | 405 | 425 | 350 | 355 | 370 | 12-Ø23 | 12-Ø28 | 12-Ø31 | Ø319 | Ø319 | Ø330 |
| 300 | 850 | 538 | 460 | 460 | 485 | 400 | 410 | 430 | 12-Ø23 | 12-Ø28 | 16-Ø31 | Ø370 | Ø370 | Ø389 |
Product features
Automatic hydraulic balance, solves uneven heating issues. This valve automatically locks the pressure difference between supply and return pipelines. It distributes water flow evenly across all branches, eliminating the common engineering problem of strong flow at near ends and insufficient flow at remote ends. It keeps the entire heating or cooling system operating in a balanced state all year round.
As a pressure differential valve factory. Reduces pump load and saves long-term energy cost. Unbalanced pipe networks cause frequent pressure fluctuations, making circulation pumps work under unstable loads and consume extra power. By stabilizing system pressure difference, the valve allows the water pump to run steadily at rated efficiency, effectively reducing invalid energy consumption. For residential communities, commercial buildings and factory heating systems, it brings obvious energy-saving benefits.
Fully mechanical operation, zero daily maintenance. The valve relies purely on water pressure induction to work, without electricity, sensors or intelligent control modules. After one-time installation, it can automatically adapt to different operating conditions regardless of seasonal temperature changes or flow fluctuations. It greatly reduces manual debugging work and later maintenance pressure for property management and engineering contractors.
Excellent compatibility for new installation and old pipe renovation. Whether it is a newly built central heating project, central air-conditioning water circulation system, or aging pipe network renovation, this differential pressure valve can be directly installed and matched. It effectively eliminates pipeline noise, water hammer and flow disorder, helping projects pass hydraulic balance acceptance smoothly.
Application
For multi-branch heating and cooling pipe networks with unbalanced water flow, installing a pressure control valve is the most cost-effective solution to improve system efficiency. If your project suffers from remote-end insufficient heating, fluctuating water pressure and high pump power consumption, this automatic differential pressure balancing valve can greatly optimize overall system performance. It is a standard and necessary accessory for modern HVAC and heating engineering.
FAQ
Q: What is a OEM pressure differential valve used for?
A: It is a hydraulic balancing valve that keeps a stable pressure difference between supply and return pipes, balancing water flow and solving unbalanced heating or circulation issues.
Q: Does this valve save energy for heating systems?
A: Yes, it stabilizes pipeline operation, reduces pump load fluctuation and unnecessary energy consumption, realizing long-term energy saving and stable system operation.
Q: Is professional debugging required after installation?
A: No manual adjustment is needed. The valve works automatically through water pressure induction, which greatly reduces operation and maintenance costs.
Q: Can it be used for old pipe network renovation?
A: Absolutely. It effectively improves hydraulic imbalance, pipeline noise and unstable water flow in aging pipe systems.
Hot Tags: pressure differential valve, China pressure differential valve manufacturers, suppliers, factory, control valve, Float Control Valve, High Pressure Relief Valve, Pressure Differential Valve, Pressure Reduce Valve, Surge Anticipation Valve